← Back to dashboard
Flo-0004GOscoped
Ben Smith
1847 Fillmore St NE, Minneapolis
Sales rep: BenPhone: 763-568-8937Email: smithben1983@gmail.comScoped: Apr 20, 2026, 2:48 AM
No Drive folder
Flo's scope
Access type
Floor cleanout
Cleanout type
sweep
Total length
66 ft
Overshot / seal
— / —
Pipe segments
- 0–6 ft · 4 inch · cast iron
- 6–66 ft · 6 inch · clay
Liner plan
Option A — Stretch liner: Single pull, handles 4" to 6" transition natively. Preferred given bends. Option B — Scrim + transition liner 15/85/3: 15 ft of 4" (covers 6 ft actual + buffer), 3 ft transition, 85 ft of 6" (covers 60 ft actual + buffer). Solid fit with room for pullback.
Pre-job steps
Floor Break Up (FBU): No Descaling: No Jetting: No
Heads-up
None
Job ticket
Job Ticket — Marvel Sewer & Drain Date Scoped: 2025-01-31 Sales Rep: Ben CUSTOMER Name: Ben Smith Address: 1847 Fillmore St NE Phone: 763-568-8937 Email: smithben1983@gmail.com PIPE LAYOUT 0–6 ft: 4 inch cast iron 6–66 ft: 6 inch clay Total Length: 66 linear feet Main Connection: Wye (6"–9" approx — verify on site) LINER PLAN Option A — Stretch liner: Single pull, handles 4" to 6" transition natively. Preferred given bends. Option B — Scrim + transition liner 15/85/3: 15 ft of 4" (covers 6 ft actual + buffer), 3 ft transition, 85 ft of 6" (covers 60 ft actual + buffer). Solid fit with room for pullback. BENDS Count: 2 Details: 22.5° at 4 ft, 22.5° at 60 ft PIPE CONDITIONS / DAMAGE Root intrusion (minor) at 22–55 ft — camera passed through easily. Flexshaft will clear on liner day, standard prep. WORK SCOPE Liner Start: 3 ft from access (remote start covers 0–3 ft, past laundry tie-in at 2 ft) Liner End: 66 ft — stops at main Remote Start Note: After curing, Clog Dog cuts out the 0–3 ft remote start section. Laundry tie-in at 2 ft is left fully open — no reinstatement needed. Patches: None Overshot Cutback: No ACCESS Type: Floor cleanout (sweep) Cleanout Type: Sweep Notes: Easy access, no obstructions PRE-JOB REQUIREMENTS Floor Break Up (FBU): No Descaling: No Jetting: No GROUND CONDITIONS Trailer within 100 ft: Yes VIDEO LINK https://drive.google.com/file/d/1KW5ve0wuJIRoDDhUZ4xLLURWXLuihMmZ/view?usp=drivesdk FLO ASSESSMENT Verdict: GO Flags: None Summary: Straightforward 66 LF lined run from a sweep cleanout. Cast iron transitions to clay at 6 ft — install team should confirm clay pipe size before pulling liner (standard check on this pipe type). Two mild 22.5° bends, camera sailed through without issue. Minor roots at 22–55 ft cleared by Flexshaft on liner day. Laundry tie-in at 2 ft stays fully open after remote start is cut out — no reinstatement needed. PERMIT REQUIREMENTS City: Minneapolis Permit Type: Minneapolis Sewer Permit How to Apply: Verify with office Cost: $160.00 Inspection Process: Verify with office Road Patch Requirement: N/A Road Closure: N/A I&I Program: N/A Notes: If any work enters the ROW, a separate Minneapolis ROW Excavation Permit ($800) is required. This job appears to be interior/no-dig — standard sewer permit should apply. HEADS UP — INSTALL TEAM ATTENTION None ADDITIONAL NOTES Install team: Confirm clay pipe size after the cast iron section before pulling liner. Usually 6" but occasionally 4" or 5" — quick check saves a wasted liner. Full liner footage billed is 66 LF. Remote start covers 0–3 ft (past laundry tie-in at 2 ft) — Clog Dog cuts it out post-cure.
Install feedback (0)
No feedback submitted yet.
Flo conversation (scoping)
Flo
Hi! I'm Flo. Map the pipe layout on the left and click "Scope with Flo" — or just describe the job here and I'll guide you through.
You
Here are the job details I have so far:
Customer: Ben Smityh
Address: 1847 Fillmore St NE
Phone: 76356888
Email: smithben1983@gmail.com
Sales Rep: Ben
Pipe Layout (access point → main connection):
0' to 6': 4 inch cast iron
6' to 66': 6 inch clay
Total Length: 66 linear feet
Pipe Conditions:
Root intrusion (minor — worst case) at 22-55 ft
Bends:
22.5° at 4 ft from access
22.5° at 60 ft from access
Tie-in Laterals (observed during camera):
2" tie-in at 2 ft — Laundry
Proposed Scope (what was sold):
Liner : 3' to 66' (63 LF)
Main Connection: Wye
Main Size: 6"-9" (approx)
Access Type: Floor cleanout (sweep)
Ground Conditions: Trailer within 100ft: Yes
Video Link: https://drive.google.com/file/d/1KW5ve0wuJIRoDDhUZ4xLLURWXLuihMmZ/view?usp=drivesdk
Please assess this job and let me know if you need any additional information.
Flo
A couple of things to sort out on the customer info before we dive in:
1. The name looks like it might have a typo — is it **Ben Smith**?
2. The phone number appears to be missing a digit — can you confirm the full number? (Looking for something like **763-568-8837**?)
You
1. yes 2. 7635688937
Flo
CORRECTIONS_START
{"customer_name": "Ben Smith", "customer_phone": "763-568-8937"}
CORRECTIONS_END
Got it — Ben Smith, 763-568-8937. Now let's scope this job.
A few quick questions:
1. The proposed scope shows the liner running **3' to 66' (63 LF)**. Just to confirm — the liner starts at 3 ft because of the laundry tie-in at 2 ft, right? That would make the remote start section 3 ft inside the pipe, which is well within the 15 ft limit. And to be clear, the full 66 LF is what gets billed, not 63 LF.
2. What's the access situation in the basement — is the sweep cleanout easy to get to, or is it in a tight spot (against a wall, near a water meter, anything like that)?
3. Do you know if there's a camera video already done on this run? You've included a video link — has the camera made it through the full 66 ft without any trouble?
You
1. Correct 2. Easy to get to 3. Made it easy. roots are not to bad
Flo
Perfect — that's all I need. Let me put this together.
A couple of things to note before the ticket:
**Liner footage:** The correct bill is **66 LF**, not 63 LF. The remote start covers the 0–3 ft section (past the laundry tie-in at 2 ft), and after curing the Clog Dog cuts it out — leaving the tie-in fully open. No reinstatement needed. The full 66 ft of liner material is what gets ordered and billed.
**Liner plan:** This is a 4"→6" transition run. Two options:
- **Option A — Stretch liner:** Single pull, handles the 4"→6" transition on its own. Slightly preferred given the two 22.5° bends (minor, but stretch takes turns more cleanly).
- **Option B — Scrim + transition liner:** The 4" section is 6 ft and the 6" section is 60 ft. The **15/85/3** transition liner covers both (15 ft ≥ 6 ft ✓, 85 ft ≥ 60 ft ✓) with good buffer. Next tightest would be 12/60/3 but the 6" section is exactly 60 ft — no buffer for pullback on bends, so 15/85/3 is the safer pick.
**Roots:** Minor, camera sailed through — Flexshaft will handle these on liner day as standard prep. No pre-job crew needed.
---